McQuay M5WSS Manual de instalación Pagina 167

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 216
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 166
M5WMWS025GR/M5WSS025AR
Heating mode (Heatpump)
Water Flow Rate = 0.84 m
3
/hr
Water Flow Rate = 1.96 m
3
/hr
Water Flow Rate = 1.40 m
3
/hr
Note:
1. TC = Total Capacity, EWT = Entering Water Temperature
2. All datas above are generated at delta T = Entering Water Temperature - Leaving Water Temperature = 5
°C
164
EWT Capacity
(°C) (kW) 15 17 19 20 22 24 27 30
10
TC
5.86 5.75 5.63 5.57 5.46 5.35 5.18 5.01
12
TC
6.16 6.04 5.92 5.87 5.75 5.63 5.46 5.28
15
TC
6.60 6.48 6.36 6.30 6.18 6.06 5.87 5.68
20
TC
7.34 7.22 7.10 7.03 6.91 6.77 6.56 6.35
25
TC
7.92 7.79 7.65 7.59 7.45 7.29 7.05 6.81
30
TC
8.51 8.36 8.21 8.14 7.99 7.81 7.55 7.28
32
TC
8.74 8.59 8.44 8.36 8.21 8.02 7.75 7.47
35
TC
9.09 8.93 8.77 8.69 8.53 8.34 8.04 7.75
EWT Capacity
(°C) (kW) 15 17 19 20 22 24 27 30
10
TC
6.21 6.09 5.96 5.90 5.78 5.66 5.49 5.31
12
TC
6.52 6.40 6.27 6.21 6.09 5.96 5.78 5.59
15
TC
6.99 6.87 6.74 6.68 6.55 6.42 6.22 6.02
20
TC
7.78 7.65 7.52 7.45 7.32 7.17 6.95 6.72
25
TC
8.39 8.25 8.11 8.04 7.89 7.72 7.47 7.22
30
TC
9.01 8.85 8.70 8.62 8.46 8.28 7.99 7.71
32
TC
9.26 9.10 8.93 8.85 8.69 8.50 8.20 7.91
35
TC
9.63 9.46 9.29 9.21 9.04 8.83 8.52 8.21
EWT Capacity
(°C) (kW) 15 17 19 20 22 24 27 30
10
TC
6.47 6.34 6.21 6.15 6.02 5.90 5.72 5.53
12
TC
6.80 6.67 6.54 6.47 6.34 6.21 6.02 5.83
15
TC
7.28 7.15 7.02 6.95 6.82 6.68 6.48 6.27
20
TC
8.10 7.96 7.83 7.76 7.63 7.47 7.24 7.00
25
TC
8.74 8.59 8.44 8.37 8.22 8.05 7.78 7.52
30
TC
9.38 9.22 9.06 8.98 8.82 8.62 8.33 8.03
32
TC
9.64 9.47 9.31 9.22 9.06 8.85 8.55 8.24
35
TC
10.03 9.85 9.68 9.59 9.41 9.20 8.87 8.55
INDOOR DB (°C)
INDOOR DB (°C)
INDOOR DB (°C)
Vista de pagina 166