M5WMWS010GR/M5WSS010AR
Heating mode (Heatpump)
Water Flow Rate = 0.31 m
3
/hr
Water Flow Rate = 0.71 m
3
/hr
Water Flow Rate = 0.51 m
3
/hr
Note:
1. TC = Total Capacity, EWT = Entering Water Temperature
2. All datas above are generated at delta T = Entering Water Temperature - Leaving Water Temperature = 5
°C
160
EWT Capacity
(°C) (kW) 15 17 19 20 22 24 27 30
10
TC
2.42 2.38 2.33 2.30 2.26 2.21 2.14 2.07
12
TC
2.55 2.50 2.45 2.43 2.38 2.33 2.26 2.18
15
TC
2.73 2.68 2.63 2.61 2.56 2.50 2.43 2.35
20
TC
3.04 2.98 2.93 2.91 2.86 2.80 2.71 2.62
25
TC
3.28 3.22 3.16 3.14 3.08 3.02 2.92 2.82
30
TC
3.52 3.46 3.40 3.37 3.30 3.23 3.12 3.01
32
TC
3.61 3.55 3.49 3.46 3.39 3.32 3.20 3.09
35
TC
3.76 3.69 3.63 3.59 3.53 3.45 3.32 3.20
EWT Capacity
(°C) (kW) 15 17 19 20 22 24 27 30
10
TC
2.57 2.52 2.47 2.44 2.39 2.34 2.27 2.20
12
TC
2.70 2.65 2.59 2.57 2.52 2.47 2.39 2.31
15
TC
2.89 2.84 2.79 2.76 2.71 2.65 2.57 2.49
20
TC
3.21 3.16 3.11 3.08 3.03 2.96 2.87 2.78
25
TC
3.47 3.41 3.35 3.32 3.26 3.19 3.09 2.98
30
TC
3.72 3.66 3.60 3.56 3.50 3.42 3.30 3.19
32
TC
3.83 3.76 3.69 3.66 3.59 3.51 3.39 3.27
35
TC
3.98 3.91 3.84 3.81 3.74 3.65 3.52 3.39
EWT Capacity
(°C) (kW) 15 17 19 20 22 24 27 30
10
TC
2.67 2.62 2.57 2.54 2.49 2.44 2.36 2.29
12
TC
2.81 2.76 2.70 2.68 2.62 2.57 2.49 2.41
15
TC
3.01 2.96 2.90 2.88 2.82 2.76 2.68 2.59
20
TC
3.35 3.29 3.24 3.21 3.15 3.09 2.99 2.90
25
TC
3.61 3.55 3.49 3.46 3.40 3.33 3.22 3.11
30
TC
3.88 3.81 3.75 3.71 3.65 3.56 3.44 3.32
32
TC
3.99 3.92 3.85 3.81 3.74 3.66 3.53 3.41
35
TC
4.15 4.07 4.00 3.96 3.89 3.80 3.67 3.53
INDOOR DB (°C)
INDOOR DB (°C)
INDOOR DB (°C)