M5CCWS060CR/M5WST060AR
Heating mode (Heatpump)
Water Flow Rate = 2.07 m
3
/hr
Water Flow Rate = 3.45 m
3
/hr
Water Flow Rate = 4.83 m
3
/hr
Note:
1. TC = Total Capacity, EWT = Entering Water Temperature
2. All datas above are generated at delta T = Entering Water Temperature - Leaving Water Temperature = 5
°C
147
EWT Capacity
(°C) (kW) 15 17 19 20 22 24 27 30
10
TC
13.15 12.89 12.63 12.50 12.24 11.99 11.62 11.25
12
TC
13.82 13.55 13.29 13.16 12.89 12.63 12.24 11.85
15
TC
14.81 14.54 14.27 14.14 13.87 13.59 13.17 12.74
20
TC
16.47 16.19 15.92 15.78 15.50 15.19 14.71 14.24
25
TC
17.77 17.47 17.17 17.02 16.72 16.36 15.82 15.28
30
TC
19.08 18.75 18.42 18.26 17.93 17.53 16.93 16.33
32
TC
19.60 19.26 18.92 18.75 18.41 18.00 17.37 16.75
35
TC
20.39 20.03 19.67 19.50 19.14 18.70 18.04 17.38
EWT Capacity
(°C) (kW) 15 17 19 20 22 24 27 30
10
TC
13.93 13.65 13.38 13.24 12.96 12.70 12.31 11.91
12
TC
14.63 14.35 14.07 13.93 13.65 13.38 12.96 12.54
15
TC
15.68 15.40 15.12 14.97 14.69 14.39 13.94 13.49
20
TC
17.44 17.15 16.86 16.71 16.42 16.08 15.58 15.08
25
TC
18.82 18.50 18.18 18.02 17.70 17.32 16.75 16.19
30
TC
20.21 19.86 19.51 19.33 18.99 18.56 17.93 17.30
32
TC
20.76 20.40 20.04 19.86 19.50 19.06 18.40 17.74
35
TC
21.59 21.21 20.84 20.65 20.27 19.80 19.10 18.40
EWT Capacity
(°C) (kW) 15 17 19 20 22 24 27 30
10
TC
14.51 14.22 13.94 13.79 13.50 13.23 12.82 12.41
12
TC
15.24 14.95 14.66 14.52 14.22 13.94 13.50 13.07
15
TC
16.34 16.04 15.75 15.60 15.30 14.99 14.53 14.06
20
TC
18.17 17.86 17.56 17.41 17.10 16.75 16.23 15.71
25
TC
19.61 19.27 18.94 18.77 18.44 18.05 17.45 16.86
30
TC
21.05 20.69 20.32 20.14 19.78 19.34 18.68 18.02
32
TC
21.63 21.25 20.88 20.69 20.31 19.85 19.17 18.48
35
TC
22.49 22.10 21.70 21.51 21.11 20.63 19.90 19.17
INDOOR DB (°C)
INDOOR DB (°C)
INDOOR DB (°C)
Comentarios a estos manuales