McQuay MCK030A Manual de instalación Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 54
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
Page 23
Model : MCK 020AR / MWSC 020BR MCK 030AR / MWSC 030BR
MCM 020DR / MWSC 020BR MCM 030DR / MWSC 030BR
1) Electrical connection
Indoor unit
Terminal block
Outdoor unit
Terminal block
There must be a double pole
switch with minimum 3 mm
contact gap in the fixed
installation circuit.
Power supply wire
220-240V/1Ph/50Hz
Connecting cable
N
COMP
4WV
A
N
L
N
COMP
4WV
A
W
F
F
E
N
L
2) Electrical parameter
Model
Indoor unit MCK 020AR MCK 030AR MCM 020DR MCM 030DR
Outdoor unit MWSC 020BR MWSC 030BR MWSC 020BR MWSC 030BR
Power source (V/Ph/Hz) 220-240 / 1 / 50
Power input
(W)
Cooling 1560 2420 1530 2250
Heating 1580 2445 1560 2460
Running current
(A)
Cooling 7.1 11.8 7.0 10.2
Heating 7.2 11.97.2 11
Power supply wire
Section area(mm²) 2.0 3.3 4 4
Quantity 3333
Connecting cable
Section area (mm²) 3.3 3.3 4 4
Quantity 5555