Model: MCC 030M / MWSC 030B
The temperature sensor wire connecting outdoor unit with indoor unit
The malfunction wire connecting outdoor unit with indoor unit
Power supply cable
220-240V/1Ph /50Hz
Indoor
terminal block
Connecting cable
Outdoor
terminal block
There must be a double pole
switch with minimum 3mm contact
gap in the installation circuit.
N
L
E1
E2
E3
COMP
L
N
F
L
N
COMP
WV
N
L
E
L
N
2) Electrical parameter
Model
Indoor unit MCC 010M MCC 015M MCC 020M MCC025M MCC 030M
Outdoor unit MWSC 010B MWSC 015B MWSC 020B MWSC025B MWSC 030B
Power source 220V~/50Hz
Power input(W) Cooling 740 1,700 1,635 1,800 2,350
Running current(A) Cooling 3.5 5.5 7.58.311.1
Power supply wire
Section
area(mm²)
2.5 2.5 2.52.52.5
Quantity 33333
Connecting cable
Section
area(mm²)
2.5 2.5 2.5 2.5 2.5 1.5
Quantity 333322
ó The wiring must be fi rmly connected.
ó Electric wiring must not touch the refrigerant pipe, compressor and moving parts of the fan motor.
ó The wiring between indoor unit and outdoor unit must be fi xed by clamp.
ó All wiring between indoor unit and outdoor unit should be neoprene copper core, and section area of cable
should be in accordance with above requirements.