Insufficient Cooling
High Discharge Pressure or Low
Suction Pressure
Dual Pressure
Switch
Compressor
Cycling
Overcurrent
Relay For
Compressor
Clogged Capillary or Pressure
Switch
Switch Faulty
High Voltage or Low Voltage
Discharge Gas
Thermostat or
Internal
Thermostat
Single-Phase
High Discharge Pressure And
High Suction Pressure
High Discharge Pressure And
Low Suction Pressure
Refrigerant Short Charge or
Refrigerant Leakage
See "High Discharge Pressure" or
"Low Suction Pressure"
Repair clogging and replace the
switch if required
Repair or change if necessary
Get the right voltage
Check the power line to the
compressor : repair when necessary
High Suction Pressure
High Discharge Pressure or Low
Suction Pressure
See "High Suction Pressure"
Running
Tripping
Cycling On
Tripping
Tripping
Loose Connections
See "High Discharge Pressure"
or "High Suction Pressure"
Tighten the connections
See "High Discharge Pressure"
or "Low Suction Pressure"
Add refrigerant. Repair
leakage if detected.
See "High Discharge Pressure"
or "Low Suction Pressure"
43 44
Noisy Operation
Unremoved Shipping Bolt(s)
Evaporator
Fan
Compressor
Overcharged Refrigerant
Low Suction Pressure
Worn Compressor Parts
Knocking Runner
Worn Bearing
Refrigerant Short Charge
Remove the bolt(s)
Purge the refrigerant
See "Low Suction Pressure"
Replace or repair the compressor
Fix the runner or casing properly
Noisy
Partially Clogged Clean the dryer
Add refrigerant
Change the bearing
Liquid Line
Shipping
Bolt(s)
Liquid
Refrigerant
Backing Up
Noisy
Noisy
Inadequate Duct Work
Loose Fixed Screws Tighten all fixed screws
Check flexible ducts
Noisy
Strainer
Whistling
Insufficient Cooling
Noisy Operation
General Trouble Shooting Guide - 1
When any air conditioner malfunction is noted, immediately switch off the power sup-
ply to the unit, and contact the local dealer, if necessary. Some simple troubleshooting
tips are given below:
Fault Cause
1. Compressor does not work * Protection against frequent starting.
3 minutes after starting. Wait for 3 to 4 minutes
2. The unit does not work. * Power failure or need to replace the
fuse
* The power plug is disconnected.
* It is possible that your delay timer has
been set incorrectly.
* If the fault persist after the verifications,
contact your installer.
3. The air flow is too low * The air filter is dirty
* The door and windows are opened.
* The air intake and discharge area are
clogged.
4. The remote control light is dim. * Battery flat.
* Batteries are incorrectly inserted or
misplaced.
5. Air discharge flow has bad odour * Odours may be caused by cigarette,
smoke particles, perfume etc. which
adhere to the coil.
* Check if there is any moisture on the
wall, garment, and others.
* Check the drain pan
6. Condensation on the front panel. * This is due to air humidity after a long
time operation.
* The set temperature is too low.
Increase the temperature and change it
to high fan.
7. Hissing sound during operation. * Refrigerant flow into evaporator coil.