B. WALL MOUNTED HEATPUMP SERIES
Model Board Handset
WM 10/15/20/25 FR C2.4 G8
LED Indicator Light Display
Cooling Mode Dry Mode
(Green) (Orange)
Heat / Fan Mode Sleep Mode
(Red/Green) (red)
25
Self Diagnosis Table
COOL DRY FAN HEAT SLEEP
Operation / Faulty Indication
/ Cooling mode
Dry mode
Fan mode
/ Heat mode
/ Auto mode in heating operation
/ Auto mode in cooling operation
Defrost operation
Controller overload protection / gas not enough
Indoor coil sensor contact loose / short
Outdoor coil sensor contact loose / short
Room air sensor contact loose / short
If the system is in auto or sleep mode, switch to
heat or cool mode and turn off the sleep
function, turn off the power supply to reset the
system, wait for 3 minutes and on the system
again
If the system is in cool or heat mode ( with the
sleep function off ), the sensor may have
contact problem, compressor overload
protection trip or outdoor abnormal operating
condition.
ON / ON or OFF BLINKING
C. CEILING EXPOSED COOLING /
HEATPUMP SERIES - WIRELESS CONTROL
Model Board Handset
CE 20/25/30/40/50 D/DR C3.0B G8
Cooling : LED Indicator Light Display
COOL DRY FAN
Heatpump : LED Indicator Light Display
COOL DRY TIMER FAN POWER HEAT
Self Diagnosis Table
COOL DRY/ FAN/ HEAT Operation / Faulty Indication
TIMER POWER
/ / / Power on
Room sensor contact loose / short
Outdoor coil sensor contact loose / short
Gas leak
Compressor overload
Outdoor defrost
26
ON / ON or OFF BLINKING