Normal Running Mode Condition
2
If the air conditioner unit has no faulty indications and the compressor is running at normal mode, the
outdoor P.C.Board’s LED indication will blink at a slower paste. The table below shows the significant
meaning of different running mode and limitation for this air conditioner unit.
One must not attempt to see the LED indication blinking unless instructed to do so.
Blinks Blinking Indication
1 Normal Running, with no limitation
2 Voltage Limit
3 Cooling unit : Outdoor Coil Temperature Limit
4 Total Current Limit
5 Discharge Temperature Limit
6 Cooling unit : Indoor Coil Temperature Limit
7 Indoor Fan Control
8 Outdoor Frequency Adjustment
(Applicable to Inverter System Only)