8. Wiring
Important: The figures shown in the table are for information purpose only. They should be checked and selected
to comply with the local/national codes of regulations. This is also subject to the type of installation
and conductors used.
All wires must be firmly connected
All wires must not touch the refrigerant piping, compressor or any moving parts of the fan motor.
The connecting wires between the indoor unit and the outdoor unit must be clamped on the wire
clamps as shown in the figure.
The power supply cord must be equivalent to H05RN-F (245IEC57) which is the minimum requirement.
Model M5LCX 010/015C/CR M5LCX 020/025C/CR
Power supply cable size (mm
2
)
1.5 2.5
Number of wire 3 3
Interconnection cable size (mm
2
)
1.5 2.5
Number of wire 3 3
Recommended time delay fuse (A) 15 20
Voltage range 220V-240V / 1 Ph / 50Hz +