McQuay MDS300B Manual de usuario Pagina 28

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 30
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 27
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
A B C D E F G
Specification for AMDS
AMDS080BR AMDS100BR
Btu/h 83,594 95,536
W 24,500 28,000
Btu/h 88,712 102,360
W 26,000 30,000
W 7,500 8,500
W 7,200 8,300
AMDS080B AMDS100B
Btu/h 83,594 95,536
W 24,500 28,000
W 7,500 8,500
V/Ph/Hz 380/3/50 380/3/50
R22 R22
HI-FAN l/s / cfm 3194/6768 3194/6768
LOW-FAN l/s / cfm 1528/3237 1528/3237
dB(A) 62 64
HEIGHT mm/in 1840/72.4 1840/72.4
WIDTH mm/in 990/39.0 990/39.0
DEPTH mm/in 840/33.0 840/33.0
kg/lb 275/606 385/628
Flare/Brazed Flare/Brazed
LIQUID mm/in 12.7/0.5 12.7/0.5
GAS mm/in 28.6/1.125 28.6/1.125
AMDS180BR AMDS200BR
Btu/h 162,070 170,600
W 47,500 50,000
Btu/h 170,600 180,836
W 50,000 53,000
W 14,100 15,200
W 13,200 14,700
AMDS180B AMDS200B
Btu/h 162,070 170,600
W 47,500 50,000
W 14,100 15,200
POWER SOURCE
MODEL
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
OUTDOOR UNIT
AIR FLOW
SOUND PRESSURE LEVEL
UNIT WEIGHT
PIPE CONNECTION
MODEL
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL TOTAL INPUT POWER
MODEL
OUTDOOR UNIT
MODEL
OUTDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
SIZE
UNIT DIMENSION
POWER SOURCE
REFRIGERANT TYPE
TYPE (LIQUID/GAS)
S5
MCCD 060C
Btu/h 56000
kW 16.4
Btu/h 63100
kW 18.5
V/Ph/Hz
l/s / CFM 779 / 1650
l/s / CFM 722 / 1530
l/s / CFM 675 / 1430
l/s / CFM 609 / 1290
EXTERNAL STATIC PRESSURE (H/M/L)
Pa (in.wg.)
176/157/137/98(0.71/0.63/0.55/0.39)
dBA 55 / 53 / 50 / 47
mm/in 378 / 14.88
mm/in 1499 / 59.02
mm/in 541 / 21.30
kg/lb
MCCD 040C
38200
11.2
42700
12.5
519 / 1100
500 / 1060
467 / 990
425 / 900
206/176/127/93(0.83/0.71/0.51/0.37)
51 / 49 / 45 / 41
378 / 14.88
1045 / 41.14
541 / 21.30
42 / 92.59
MCCD 050C
47800
14.0
54600
16.0
750 / 1590
651 / 1380
604 / 1280
571 / 1210
176/157/137/108(0.71/0.63/0.55/0.43)
53 / 52 / 50 / 47
378 / 14.88
1299 / 51.14
541 / 21.30
54 / 119.05 62 / 136.69
mm/in
LIQUID mm/in 12.70 / 1/2
GAS mm/in
MCCD 030C
30700
9.0
34100
10.0
425 / 900
392 / 830
359 / 760
335 / 710
206/167/127/88(0.83/0.67/0.51/0.35)
49 / 46 / 42 / 38
378 / 14.88
929 / 36.57
541 / 21.30
39 / 85.98
15.88 / 5/8
LOW
CONTROL
UNIT DIMENSION
HEIGHT
INDOOR UNIT
REFRIGERANT TYPE / CONTROL
HIGH
MEDIUM
AIR DISCHARGE
OPERATION
MODEL
AIR FLOW
SUPER HIGH
FLARE VALVE
9.52 / 3/8
19.05 / 3/4
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
WIDTH
SOUND PRESSURE LEVEL (H/M/L)
WEIGHT
PIPE CONNECTION
TYPE
SIZE
CONDENSATE DRAIN SIZE
DEPTH
R22 / EXV
DUCTED
WIRED CONTROL
19.05 / 3/4
220 - 240 / 1 / 50
NOTE :
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL SPECIFICATIONS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
HEATING - 20ºC DB / 15ºC WB INDOOR AND 7ºC DB / 6ºC WB OUTDOOR
MODEL
POWER INPUT
AIR FLOW
EXT STATIC
PRESSURE
DIMENSION
HIGH
W
CFM / m
3
/h
CFM / m
3
/h
CFM / m
3
/h
Pa
Pa
Pa
mm / in
mm / in
mm / in
175
177 / 300
118 / 220
88 / 150
70
60
50
1200 / 47.2
900 / 35.4
290 / 11.4
287
294 / 500
261 / 444
197 / 335
70
70
70
1236 / 48.6
1138 / 44.8
321 / 12.6
437
471 / 800
377 / 640
294 / 500
90
90
90
1408 / 55.4
1264 / 49.7
386 / 15.2
607
589 / 1000
471 / 800
383 / 650
110
110
100
1708 / 67.2
1345 / 52.9
433 / 17.0
720
883 / 1500
783 / 1330
683 / 1160
150
150
150
1775 / 69.9
1345 / 52.9
460 / 18.1
1400
1177 / 2000
942 / 1600
824 / 1400
150
150
150
1735 / 68.3
1687 / 66.4
600 / 23.6
MEDIUM
LOW
HIGH
MEDIUM
LOW
LENGTH
WIDTH
HEIGH
HRB 030A HRB 050A
HRB 080A HRB 100A HRB 150A HRB 200A
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
NOTE :
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
4) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
MCCD-C
HRB
INDOOR UNIT
S6
MCMD 040D MCMD 050D MCMD 062C
Btu/h 38200 47800 56000
kW 11.2 14.0 16.4
Btu/h 42700 54600 63100
kW 12.5 16.0 18.5
V/Ph/Hz
l/s / CFM 477 / 1010 491 / 1040 731 / 1550
l/s / CFM 420 / 890 448 / 950 623 / 1320
l/s / CFM 368 / 780 387 / 820 472 / 1000
dBA 54 / 53 / 52 54 / 53 / 52 56 / 53 / 46
mm/in 285 / 11.2
mm/in 1903 / 74.9
mm/in 680 / 26.8
kg/lb 85 / 187.4
mm/in
LIQUID mm/in 12.7 / 1/2
GAS mm/in
NOTE :
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
5) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
MODEL INDOOR UNIT
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
WIDTH
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
UNIT DIMENSION
HEIGHT
AIR DISCHARGE
HIGH
SOUND PRESSURE LEVEL (H/M/L)
AIR FLOW
LOW
MEDIUM
70 / 154.3
1714 / 67.40
670 / 26.30
249 / 9.80
AUTOMATIC LOUVER (UP & DOWN) & MANUAL LOUVER (BOTTOM)
WIRELESS REMOTE CONTROL
220 - 240 / 1 / 50
R22 / EXV
INDOOR UNIT
OPERATION
POWER SOURCE
REFRIGERANT TYPE / CONTROL
CONTROL
19.05 / 3/4
PIPE CONNECTION
TYPE
SIZE
9.52 / 3/8
FLARE VALVE
19.05 / 3/4
Btu/h
kW
Btu/h
kW
V/Ph/Hz
l/s / CFM
l/s / CFM
l/s / CFM
l/s / CFM
EXTERNAL STATIC PRESSURE (H/M/L) Pa (in.wg.)
dBA
mm/in
mm/in
mm/in
kg/lb
MCCD 020C
19100
5.6
21500
6.3
-
330 / 700
321 / 680
293 / 620
69/65/42(0.28/0.26/0.17)
38 / 36 / 34
261 / 10.28
1065 / 41.93
411 / 16.18
22 / 48.5
MCCD 025C
22200
6.5
25200
7.4
-
345 / 730
340 / 720
274 / 580
41/31/18(0.16/0.12/0.07)
40 / 39 / 36
261 / 10.28
1200 / 47.24
411 / 16.18
25 / 55.1
mm/in
LIQUID mm/in
GAS mm/in
MCCD 010C
9600
2.8
10900
3.2
-
142 / 300
123 / 260
104 / 220
49/39/29(0.20/0.16/0.12)
33 / 30 / 26
17 / 37.5
9.52 / 3/8
MCCD 015C
12300
3.6
13600
4.0
-
241 / 510
208 / 440
170 / 360
49/39/20(0.20/0.16/0.08)
37 / 34 / 29
21 / 46.3
12.70 / 1/2
MODEL
AIR FLOW
SUPER HIGH
DEPTH
LOW
CONTROL
UNIT DIMENSION
HEIGHT
INDOOR UNIT
REFRIGERANT TYPE / CONTROL
HIGH
MEDIUM
AIR DISCHARGE
OPERATION
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
POWER SOURCE
WIDTH
SOUND PRESSURE LEVEL (H/M/L)
WEIGHT
CONDENSATE DRAIN SIZE
261 / 10.28
765 / 30.12
411 / 16.18
261 / 10.28
905 / 35.63
411 / 16.18
220 - 240 / 1 / 50
R22 / EXV
DUCTED
WIRED CONTROL
19.05 / 3/4
PIPE CONNECTION
TYPE
SIZE
FLARE VALVE
6.35 / 1/4
15.88 / 5/8
9.52 / 3/8
NOTE :
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
4) ALL INDOOR MODELS CAN BE USED FOR COOLING ONLY OR HEATPUMP APPLICATION.
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
MCMD-D/C
MCCD-C
INDOOR UNIT
Vista de pagina 27
1 2 ... 23 24 25 26 27 28 29 30

Comentarios a estos manuales

Sin comentarios