Daikin IM 980-1 3
General Information
General Information
Thinline™ 3G Vertical Fan Coils are intended for use in single
zone applications. They are available in sizes from 200 to 1200
cfm. Figure 2 describes the main features of these units and
can be refered to for component placement. These units are
available in two-pipe configurations with one hydronic coil,
with or without electric heat. They are also available in four-
pipe configurations with one primary coil and a secondary
reheat or preheat coil. A variety of factory-built piping
packages are available, either factory or field-installed.
Units are available with a variety of thermostat and fan speed
control options, which can be mounted on the unit or shipped
loose for mounting in the controlled space. Options include:
Four-position fan switch (Off/Lo/Med/Hi).
Manual thermostat with On/Off valve control.
Digital thermostat with a variety of control opti
ons,
i
ncluding fan control, On/Off or modulating valve contro
l
an
d automatic changeover from heating to cooling on two-
pipe systems.
Low-voltage interface board for connecting a unit to
controls provided by others. The controls interface option
includes a 24 volt AC transformer and interface terminal
strips.
No Cont
rols, with pigtail connections to the unit’s fan mo
tor
w
iring harness.
Figure 1: Nomenclature (see Table 1, page 29 for complete model number description)
Figure 2: Unit Features
FC V S - 1 02 A
Unit Type
FC = Fan Coil
FH = Cabinet Unit Heater
Unit Configuration
V= Vertical
W = Wall Hung (future)
Cabinet Type
C = Cabinet (Flat Top)
S = Slope Top
H = Hideaway
Voltage
A = 115/60/1
E = 208-230/60/1
J = 277-265/60/1
Unit Size
02 = 200 CFM
03 = 300 CFM
04 = 400 CFM
06 = 600 CFM
08 = 800 CFM
10 = 1000 CFM
12 = 1200 CFM
Design Series
Multiple Control Options
From 3-speed switch to LV interface board
Remote or unit-mounted
3-speed or staged fan
Multiple
Configurations
Flat top
Slope top
Hideaway
Wall mounted
Multiple Coil Options
2, 3 or 4-row main coil
1 or 2-row preheat or 1-row
re
heat coil
Hot water or steam
Same or opposite end
connection
s
Multiple Grille Options
Stamped discharge
louver
Multi-directional grilles
Return grille option
Software Selectable
Valve & Piping Packages
Factory-mounted, wired and
teste
d or factory-assembled and
shipped loose for field mount
Normally Closed or Open, On/Off
or modulating valves
Eas
ily Removed Drain Pan & Motor Assembly
For easy maintenance and service
Sloped, polymer drain pan for good IAQ
Optional Secondary Drain Pan
(Supplied with Piping Packages)
Noncorrosive
Easily removed