MVCU - 2004
Vertical Condensing Unit
Models: MVCU 025 A/AR
MVCU 030 A/AR
MVCU 035 A/AR
MVCU 040 A/AR
MVCU 050 A/AR
MVCU 060 A/AR
Vista de pagina 0
1 2 3 4 5 6 ... 42 43

Indice de contenidos

Pagina 1 - Vertical Condensing Unit

MVCU - 2004Vertical Condensing UnitModels: MVCU 025 A/ARMVCU 030 A/ARMVCU 035 A/ARMVCU 040 A/ARMVCU 050 A/ARMVCU 060 A/AR

Pagina 2 - Contents

8Refrigerant CircuitMODEL : MVCU 025A

Pagina 3 - Features

9MODEL : MVCU 030A/035A/040A/050A/060A

Pagina 4 - Specifications

10Outlines And DimensionsMODEL : MVCU 025 / 030 / 035AMODEL A B C D E F GMVCU 025 / 030 / 035A 841 572 572 168 236 168 166All dimensions in mm

Pagina 5 - R22 / OUTDOOR CAP. TUBE

11MODEL : MVCU 040 / 050 / 060AMODEL A B C D E F GMVCU 040A 984 762 275 225 762 225 275MVCU 050 / 060A 1086 762 275 225 762 225 275All dimensions in m

Pagina 6 - R22 / OUTDOOR CAP.TUBE

12Wiring DiagramsWALL MOUNTEDINDOOR UNITMODEL : MWM 025FOUTDOOR UNITMODEL : MVCU 025A

Pagina 7

13INDOOR UNITMODEL : MWM 031FOUTDOOR UNITMODEL : MVCU 030A

Pagina 8

14CEILING CONVERTIBLEINDOOR UNITMODEL : MCM 025DOUTDOOR UNITMODEL : MVCU 025A

Pagina 9 - Operating Range

15INDOOR UNITMODEL : MCM 030DOUTDOOR UNITMODEL : MVCU 030A

Pagina 10 - Refrigerant Circuit

16INDOOR UNITMODEL : MCM 040DOUTDOOR UNITMODEL : MVCU 035A

Pagina 11

17INDOOR UNITMODEL : MCM 040 / 050DOUTDOOR UNITMODEL : MVCU 040 / 050A

Pagina 12 - Outlines And Dimensions

ContentsFeatures ... 1Specificat

Pagina 13 - MODEL : MVCU 040 / 050 / 060A

18INDOOR UNITMODEL : MCM 062COUTDOOR UNITMODEL : MVCU 060A

Pagina 14 - Wiring Diagrams

19CEILING CASSETTE A SERIESINDOOR UNITMODEL : MCK 025AOUTDOOR UNITMODEL : MVCU 025A

Pagina 15 - MODEL : MVCU 030A

20INDOOR UNITMODEL : MCK 030AOUTDOOR UNITMODEL : MVCU 030A

Pagina 16 - MODEL : MVCU 025A

21INDOOR UNITMODEL : MCK 040AOUTDOOR UNITMODEL : MVCU 035A

Pagina 17 - MODEL : MCM 030D

22INDOOR UNITMODEL : MCK 040 / 050AOUTDOOR UNITMODEL : MVCU 040 / 050A

Pagina 18 - MODEL : MVCU 035A

23CEILING CASSETTE B SERIESINDOOR UNITMODEL : MCK 025BOUTDOOR UNITMODEL : MVCU 025A

Pagina 19 - MODEL : MVCU 040 / 050A

24INDOOR UNITMODEL : MCK 030BOUTDOOR UNITMODEL : MVCU 030A

Pagina 20 - MODEL : MVCU 060A

25CEILING CONCEALEDINDOOR UNITMODEL : MCC 025COUTDOOR UNITMODEL : MVCU 025A

Pagina 21 - MODEL : MCK 025A

26INDOOR UNITMODEL : MCC 030COUTDOOR UNITMODEL : MVCU 030A

Pagina 22 - MODEL : MCK 030A

27INDOOR UNITMODEL : MCC 040COUTDOOR UNITMODEL : MVCU 035A

Pagina 23 - MODEL : MCK 040A

1FeaturesSpace SavingThe smaller base size and vertical air discharge allow compact location on multi-unit installation.Power SourceSingle phase unit

Pagina 24 - MODEL : MCK 040 / 050A

28INDOOR UNITMODEL : MCC 040 / 050 / 060COUTDOOR UNITMODEL : MVCU 040 / 050 / 060A

Pagina 25 - MODEL : MCK 025B

29Installation(1) Installation Of VCU• The unit should be installed in accordance with all national and local codes and regulations which govern thein

Pagina 26 - MODEL : MCK 030B

30Piping Sizes (Brazed Valve)Piping sizes are as follows:MODEL MVCU 025A MVCU 030A MVCU 035 / 040A MVCU 050A MVCU 060ALiquid (mm/in) 9.52 (3/8) 9.52 (

Pagina 27 - MODEL : MCC 025C

31(5) Additional Charge• The refrigerant gas has already charged into the outdoor unit. For the piping length of 5m. Additionalrefrigerant charge afte

Pagina 28 - MODEL : MCC 030C

32Service And MaintenanceWarning: Disconnect from main supply before servicingthe air conditioner.The unit is designed to give long life operation wi

Pagina 29 - MODEL : MCC 040C

33The design of the VCU outdoor series allows servicing to be carried out readily and easily. The removal ofthe top side, front and back panel make al

Pagina 30 - MODEL : MCC 040 / 050 / 060C

34TroubleshootingWhen any air-conditioner malfunction is noted, immediately switch off the power supply to the unit, andcontact the local dealer, if n

Pagina 31 - Installation

35FOR COOLING ONLY MODELSDIAGNOSIS BY FLOW CHARTThe following chart are efficient checking procedures for troubleshooting when these fan-coil units ar

Pagina 32 - (4) Vacuuming And Charging

36INSUFFICIENT COOLINGHIGH DISCHARGE PRESSURELOW DISCHARGE PRESSURELow DischargePressureMalfunction Of Fan CyclingSystemCondenserAir FlowLow Refrigera

Pagina 33 - (6) Overall Checking

37HIGH SUCTION PRESSURELOW SUCTION PRESSURENOISY OPERATIONHigh SuctionPressureExcessive Fresh Air IntakeEvaporatorAir InletTemp.Insufficient Duct Insu

Pagina 34 - Service And Maintenance

2SpecificationsWALL MOUNTED – VERTICAL CONDENSING UNIT (COOLING ONLY)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR N

Pagina 35 - CAUTION!

38Parts ListMODEL : MVCU 025ANO DESCRIPTION NO DESCRIPTION1 COIL ASSY 11 SIDE COIL GUARD2 TOP PANEL 12 COMPRESSOR3 FAN GUARD 13 ASSY, TUBE HEADER TO D

Pagina 36 - Troubleshooting

39MODEL : MVCU 030 / 035ANO DESCRIPTION NO DESCRIPTION1 COIL ASSY 11 SIDE COIL GUARD2 TOP PANEL 12 COMPRESSOR3 FAN GUARD 13 DISCHARGE TUBE ASSY4 FAN M

Pagina 37 - No Cooling

40MODEL : MVCU 040 / 050 / 060ANO DESCRIPTION NO DESCRIPTION1 COIL ASSY 11 SIDE COIL GUARD2 TOP PANEL 12 COMPRESSOR3 FAN GUARD 13 DISCHARGE TUBE ASSY4

Pagina 38 - LOW DISCHARGE PRESSURE

©2004 McQuay International +1 (800) 432-1342 www.mcquay.comISO 9002REGISTERED

Pagina 39 - NOISY OPERATION

3CEILING CONVERTIBLE – VERTICAL CONDENSING UNIT (COOLING ONLY)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2

Pagina 40 - Parts List

4CEILING CASSETTE A SERIES – VERTICAL CONDENSING UNIT (COOLING ONLY)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NO

Pagina 41 - MODEL : MVCU 030 / 035A

5CEILING CASSETTE B SERIES – VERTICAL CONDENSING UNIT (COOLING ONLY)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NO

Pagina 42

6CEILING CONCEALED – VERTICAL CONDENSING UNIT (COOLING ONLY)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2)

Pagina 43 - ISO 9002

7Outdoor temp. (°CDB)Indoor temp. (°CWB)-10-50102030405010 15 20 25 3051.7243519STDOperating RangeEnsure the operating temperature is in allowable ran