27
4. INDOOR UNIT PREPARATION
• The refrigerant piping can be routed to the unit in 5 directions, by using the cut outs in the unit casing.
• Carefully bend the pipes to the required position to align with the hole. For right hand and rear side
draw out, hold the bottom of the piping and fix direction before shaping it to the desired position. The
condensation drain hose should be taped to the pipes with vinyl tape. The electrical cable can also be
taped to the pipes.
5. MOUNTING INDOOR UNIT
• Hook the indoor unit onto the upper portion of installation plate. (Engage the 2 hooks of rear top of the
indoor unit with the upper edge of the installation plate). Ensure the hooks are properly seated on the
installation plate by moving in left and right.
1. Hook the unit into the installation plate. 2. Fix the rivet underneath after completion
of installation.
6. WATER DRAINAGE PIPING
• The indoor drain pipe must be downward gradient for smooth drainage. Avoid situation as shown in
figure below.