McQuay MWSS Guía para resolver problemas Pagina 37

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 82
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 36
MCQUAY Service Guide Book Controller Configuration
36
6.2 Multi Split Conversion
Cooling Only Model (L2.0 / L208A)
MWM-G, MCK-A/B/C/E, MCM-E, MCC-C which
are using L2 control board can be switched to
multi split units without any modification needed.
Heatpump Model (L2.0)
MWM-GR
The Multi Split mode can be selected at the slide
switch on the On/Off Switch Board; Preset at
OFF.
The outdoor coil sensor has to be removed from
the PCB as the reading is taken from the outdoor
PCB directly.
Heatpump Models (L208A)
MCK-AR/BR/CR/ER, MCM-ER, MCC-CR
The multisplit can be selected by using shunt
jumper and short jumper header MODEL_KP
between pin 1 & 2 as the picture shown below.
The outdoor coil sensor has to be removed from
the PCB as the reading is taken from the outdoor
PCB directly.
Vista de pagina 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 81 82

Comentarios a estos manuales

Sin comentarios