McQuay M4LC Especificaciones Pagina 55

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 269
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 54
General Data - Heat pump (R410A)
M5CM 050DR M5CM 062CR
M5LC 050CR M5LC 061CR
Btu/h
45500 55000
W
13340 16119
Btu/h
48000 55000
W
14070 16119
W
5020 6414
W
4720 6349
A
8.8 9.6
A
8.4 8.4
V/Ph/Hz
380 - 415 / 3 / 50 380 - 415 / 3 / 50
W/W
2.66 2.51
W/W
2.98 2.54
l/s / CFM
491 / 1040 732 / 1550
l/s / CFM
448 / 950 623 / 1320
l/s / CFM
387 / 820 472 / 1000
EXTERNAL STATIC PRESSURE (H/M/L) mmAq
00
dBA
54 / 53 / 52 56 / 53 / 46
mm/in
249 / 9.8 285 / 11.2
mm/in
1714 / 67.4 1903 / 74.9
mm/in
670 / 26.3 680 / 26.8
mm/in
345 / 13.6 368 / 14.5
mm/in
1816 / 71.4 1984 / 78.1
mm/in
760 / 29.9 760 / 29.9
kg/lb
70 / 154 85 / 187
mm/in
l/s / CFM
2171 / 4600 2171 / 4600
dBA
58 61
mm/in
850 / 33.5 850 / 33.5
mm/in
1030 / 40.6 1030 / 40.6
mm/in
400 / 15.8 460 / 18.1
mm/in
1000 / 39.4 1016 / 40.0
mm/in
1200 / 47.2 1178 / 46.4
mm/in
560 / 22.1 602 / 23.7
kg/lb
105 / 232 108 / 238
LIQUID mm/in
9.5 / 3/8 9.5 / 3/8
GAS mm/in
15.9 / 5/8 19.1 / 3/4
kg/lb
3.35 / 7.39 3.40 / 7.49
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND
1m BELOW THE UNIT.
FLARE VALVE
SOUND PRESSURE LEVEL (H/M/L)
PIPE CONNECTION
TYPE
SIZE
UNIT WEIGHT
CONDENSATE DRAIN SIZE
WIDTH
AIR FLOW
SOUND PRESSURE LEVEL
COP
REFRIGERANT CONTROL (EXPANSION DEVICE)
UNIT DIMENSION
UNIT DIMENSION
DEPTH
HEIGHT
MODEL
OUTDOOR UNIT
LOW
INDOOR UNIT
CONTROL
AIR DISCHARGE
NOMINAL COOLING CAPACITY
OPERATION
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
INDOOR UNIT
HEIGHT
WIDTH
DEPTH
PACKING
DIMENSION
HEIGHT
WIDTH
EER
REFRIGERANT CHARGE
NOMINAL RUNNING CURRENT (COOLING)
NOMINAL RUNNING CURRENT (HEATING)
POWER SOURCE
REFRIGERANT TYPE
AIR FLOW
HIGH
MEDIUM
DEPTH
DEPTH
19.1 / 3/4
R410A
OUTDOOR CAP. TUBE & TXV
OUTDOOR UNIT
UNIT WEIGHT
AUTOMATIC LOUVER (UP & DOWN) & MANUAL LOUVER (BOTTOM)
WIRELESS OR WIRED MICROCOMPUTER REMOTE CONTROL
PACKING
DIMENSION
HEIGHT
WIDTH
Vista de pagina 54