McQuay MWMV Especificaciones

Busca en linea o descarga Especificaciones para Acondicionadores de aire del sistema de división McQuay MWMV. McQuay MWMV Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 27
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
CMWV - 2004
Vertical Water Source Heat Pump
And Cooling Only Unit
Models: MWV 015 A/AR
MWV 020 A/AR
MWV 025 A/AR
MWV 030 A/AR
MWV 040 A/AR
MWV 050 A/AR
Vista de pagina 0
1 2 3 4 5 6 ... 26 27

Indice de contenidos

Pagina 1 - And Cooling Only Unit

CMWV - 2004Vertical Water Source Heat PumpAnd Cooling Only UnitModels: MWV 015 A/AR MWV 020 A/AR MWV 025 A/AR MWV 030 A/AR MWV 040 A/A

Pagina 2 - Contents

Model: MWV 025A/AR Air Flow: 1200m3/h Electrical Characteristics: 220V / 1Ph / 50Hz COOLING HEATING Water Flow (m3/h) E.W.T (oC) O.W.T (oC) E.A.T

Pagina 3 - Features

Model: MWV 030A/AR Air Flow: 1650m3/h Electrical Characteristics: 220V / 1Ph / 50Hz COOLING HEATING Water Flow (m3/h) E.W.T (oC) O.W.T (oC) E.A.T

Pagina 4 - Specifications

Model: MWV 040A/AR Air Flow: 1950m3/h Electrical Characteristics: 380V / 3Ph / 50Hz COOLING HEATING Water Flow (m3/h) E.W.T (oC) O.W.T (oC) E.A.T

Pagina 5 - Electrical Data

Model: MWV 050A/AR Air Flow: 2500m3/h Electrical Characteristics: 380V / 3Ph / 50Hz COOLING HEATING Water Flow (m3/h) E.W.T (oC) O.W.T (oC) E.A.T

Pagina 6 - Operating Limits

Dimensions Data All dimensions are approximate. Certified drawings available upon request. DIMENSIONS A B C D E F UNIT SIZE inch mm inch mm in

Pagina 7 - Water Loop System Diagram

Wiring Diagrams Model: MWV 015 / 020A Model: MWV 015 / 020 AR FM: FAN MOTORCM: COMPRESSORCOIL TEMP. SENSORWAT ER T EMP. S ENSORRE T URN A I

Pagina 8 - Performance Tables

Model: MWV 025 / 030 A Model: MWV 025 / 030 AR C1,C2: CAPACITORFM: FAN MOTORCM: COMPRESSORNLFSW: FLOW WAT ER SWITCHHP : HI GH PRESSURE S

Pagina 9 - Air Flow: 1020m

Model: MWV 040 / 050 A Model: MWV 040 / 050 AR CC: CAPACI T ORFM: FAN MOTORCM: COMPRESSORHP: HI GH PRESSUR SWITCHFSW: FLOW WATER SWITCH

Pagina 10 - Air Flow: 1200m

Transportation and Storage Upon receipt of the equipment, check the carton for visible damage. Make a notation on the shipper's delivery ticket

Pagina 11 - Air Flow: 1650m

Typical closet installation with louver door return & with ducted return Duct and attenuation Discharge ductwork is norma

Pagina 12 - Air Flow: 1950m

Contents Features ... 2 Spec

Pagina 13 - Air Flow: 2500m

Ventilation Air Outside air may be required for ventilation. The temperature of the ventilation air must be controlled so tha

Pagina 14 - Dimensions Data

Piping 1. All units are recommended to be connected to supply and return piping in a two-pipe reverse return configuration. A reverse return system i

Pagina 15 - Wiring Diagrams

8. No point in the drain system may be above the drain connection of any unit. 9. Automatic flow controlled devices must not

Pagina 16 - MODEL:AWV025AR/030AR

3. Supplemental heater and circulator pump should be shut off. All drains and vents should be opened to completely drain down the system. Short cir

Pagina 17 - MODEL:AWV040A/050A

Start-Up 1. Open all valves to full open position and turn on power to the conditioners. 2. Set thermostat for "Fan Only" operation by se

Pagina 18 - Installation

Maintenance 1. Normal maintenance on all conditioners is generally limited to filter changes. Lubrication of the fan motor is not required. 2. Filt

Pagina 19

Compressor attempts to start but doesn’t 1. Check capacitor. 2. Check for defective compressor by making resistance check on winding. 3. Check run ca

Pagina 20

©2003 McQuay International +1 (800) 432-1342 www.mcquay.comISO 9002REGISTEREDS&E

Pagina 21

Features High Energy efficiency The unit has high efficiency as the high energy/effect ratio and a Max. COP of 4.2 as well as saving the running cost

Pagina 22 - F I GURE E

Specifications MODEL MWV015A MWV015AR MWV020A MWV020AR MWV025A MWV025AR COOLING CAPACITY Btu/h 14330 19110 23890 HEATING CAPACITY Btu/h - 15360 -

Pagina 23

Airflow Correction Factors Percent of Nominal Airflow 85 90 95 100 105 110 115 Total Cooling Capillary 0.972 0.982 0.994 1.000 1.007 1.010 1.013

Pagina 24 - Start-Up

Operating Limits Air limits °C (Sl units) Cooling Heating Min. Ambient Air 19.4 21 Normal Ambient Air 26.7 21 Max. Ambient Air 35 26.7 Min. Enterin

Pagina 25 - Troubleshooting

Water Loop System Diagram drain valveair vent valveflow switchACC indoor unitAWSC outdoor unitthermometerflow switchwater supplyfiltercooling tower

Pagina 26

Performance Tables Model: MWV 015A/AR Air Flow: 760m3/h Electrical Characteristics: 220V / 1Ph / 50Hz COOLING HEATING Water Flow (m3/h) E.W.T (o

Pagina 27 - REGISTERED

Model: MWV 020A/AR Air Flow: 1020m3/h Electrical Characteristics: 220V / 1Ph / 50Hz COOLING HEATING Water Flow (m3/h) E.W.T (oC) O.W.T (oC) E.A.T

Comentarios a estos manuales

Sin comentarios